Delivery & Return:Free shipping on all orders over $50
Estimated Delivery:7-15 days international
People:15 people viewing this product right now!
Easy Returns:Enjoy hassle-free returns within 30 days!
Payment:Secure checkout
SKU:44396321
[pdf]
Southwire’s 5KV TECK 90, 5000V, non-shielded, EPR insulated power cable is a CSA approved armoured cable for industrial and commercial medium voltage applications. FT4, -40°C, HL, AG14 and 90°C rated for use in harsh Canadian environments. Rated for installation in cable trays, duct banks, direct burial, troughs, hazardous locations, continuous rigid cable supports, and is concrete encaseable.
1 AWG TECK90 5kV Copper Cable, 1 AWG TECK90 5kV Armored Power Cable,5kV TECK90 Non-Shielded EPR Power Cable, 1 AWG CSA TECK 90 Armored Cable, 1 AWG TECK90 5kV Orange PVC Jacket Cable, 1 AWG 5kV TECK90 EPR Insulated Cable.
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 131 Type TECK 90 Cable
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• CSA AG14 - Acid Gas Compliance
• ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
• Conductor: Class B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.
• Conductor Shield: Extruded semi-conducting thermosetting polymeric layer
• Insulation: No-Lead EPR (ethylene propylene rubber), Thickness: 0.090” (2.3 mm) - nominal, 90°C
• Grounding Conductor: Class B compressed or compact stranded bare copper, in accordance with ASTM B3 and B8
• Binder: Polypropylene tape
• Inner Jacket: Black PVC, Thickness: No. 2 AWG to No. 3/0 AWG = 0.080” (2.0 mm); No. 4/0 AWG to 500 kcmil = 0.110” (2.8 mm); 750 kcmil to 1000 kcmil = 0.140” (3.6 mm)
• Armor: Aluminum Interlocked Armour (AIA)
• Overall Jacket: Orange PVC (optional colours available), Thickness: No. 2 AWG to 250 kcmil = 0.060” (1.5 mm); 350 kcmil to 750 kcmil = 0.075” (1.9 mm); 1000 kcmil = 0.090” (2.3 mm)
• Size: 1 AWG
• Conductor Number: 3
• Number of Strands: 19
• Diameter Over Conductor (inch): 0.322
• Insulation Thickness (Mil): 90
• Ground No. x AWG: 1x6
• Inner Jacket Thickness (mil): 85
• Diameter Over Armor (inch): 1.682
• Overall Jacket Thickness (mil): 55
• Approx. OD (In): 1.792
• Approx. Weight (Lbs/1000'Ft): 1788
• Min Bending Radius (In): 12.5
• Max Pull Tension lb: 2008
• Allowable Ampacity In Air 90°C (Amp): 197